For 0.90-1.00mm Insulated Conductor
â3pcsâ, loading bar + windmill guide
Standard Cat 6 unshielded modular plugs accept 24 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. The âguideâ helps to separate each pair and keep its twist ratio. The âloading barâ is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass âCat 6 Patch Cord Test Limitâ. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
â2pcsâ, 4-up/4-down loading bar
Standard Cat 6 unshielded modular plugs accept 23 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The â4-up/4-down loading barâ is made in two rows. It allows you to artfully enlarge the spacing between âpin 3 to pin 4â and âpin 5 to pin 6â. In this way, the noise between the blue and green pair can be mitigated so as to easily pass âCat 6 Patch Cord Test Limitâ. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
â2pcsâ, 6-up/2-down loading bar
Standard Cat 6 unshielded modular plugs accept 23 to 26AWG, solid or stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The â6-up/2-down loading barâ is made in two rows. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 1.05-1.15mm Insulated Conductor
â2pcsâ, 4-up/4-down loading bar
The âBig Conductorâ Cat 6 unshielded modular plugs accept from 24 to 26AWG, U/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.0mm. 2-piece design. The â4-up/4-down loading barâ is made in two rows. It allows you to artfully enlarge the spacing between âpin 3 to pin 4â and âpin 5 to pin 6â. In this way, the noise between the blue and green pair can be mitigated so as to easily pass âCat 6 Patch Cord Test Limitâ. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
â2pcsâ, 4-up/4-down loading bar
Standard Cat 6 shielded modular plugs accept 23 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The â4-up/4-down loading barâ is made in two rows. It allows you to artfully enlarge the spacing between âpin 3 to pin 4â and âpin 5 to pin 6â. In this way, the noise between the blue and green pair can be mitigated so as to easily pass âCat 6 Patch Cord Test Limitâ. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
â2pcsâ, 6-up/2-down loading bar
Standard Cat 6 shielded modular plugs accept 23 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The â6-up/2-down loading barâ is made in two rows. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
â3pcsâ, loading bar + windmill guide
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The âwindmill guideâ helps to separate each pair and keep its twist ratio. The âloading barâ is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass âCat 6 Patch Cord Test Limitâ. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
Plug includes Boot w/Icon
Plug + Ï6.7mm Boot + Boot Icon
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The âwindmill guideâ helps to separate each pair and keep its twist ratio. The âloading barâ is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass âCat 6 Patch Cord Test Limitâ. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
Plug includes Boot w/Icon + Cable SR
Plug + Ï6.7mm Boot + Boot Icon + Cable SR
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The âwindmill guideâ helps to separate each pair and keep its twist ratio. The âloading barâ is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass âCat 6 Patch Cord Test Limitâ. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 1.05-1.15mm Insulated Conductor
â2pcsâ, 4-up/4-down loading bar
The âBig Conductorâ Cat 6 shielded modular plugs accept from 23 to 24AWG, F/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. 2-piece design. The â4-up/4-down loading barâ is made in two rows. It allows you to artfully enlarge the spacing between âpin 3 to pin 4â and âpin 5 to pin 6â. In this way, the noise between the blue and green pair can be mitigated so as to easily pass âCat 6 Patch Cord Test Limitâ. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 1.05-1.15mm Insulated Conductor
â2pcsâ, 4-up/4-down loading bar
The âBig Conductor w/Grounding Barâ Cat 6 shielded modular plugs accept from 23 to 24AWG, F/UTP and S/FTP twisted pair cable with accommodation of insulated conductor from 1.05mm to 1.15mm and cable O.D. less than 6.5mm. Grounding is facilitated by the external grounding bar. 2-piece design. The â4-up/4-down loading barâ is made in two rows. It allows you to artfully enlarge the spacing between âpin 3 to pin 4â and âpin 5 to pin 6â. In this way, the noise between the blue and green pair can be mitigated so as to easily pass âCat 6 Patch Cord Test Limitâ. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
â3pcsâ, 6-up/2-down load bar + windmill guide
Standard Cat 6A unshielded modular plugs accept from 24AWG to 26AWG, stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. The âguideâ helps to separate each pair and keep its twist ratio. The â6-up/2-down loading barâ is made in two rows. It facilitates moving the green pair away from the other pairs. This could provide many field installers with exactly what they need to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
â3pcsâ, one-row load bar + windmill guide
Standard Cat 6A unshielded modular plugs accept from 24AWG to 26AWG, stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. Effective pair separation and maintaining the twist ratio are made possible by the "windmill guide". Together with the âloading barâ attached to it so each wire can be trimmed flush and steadily seated. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.95-1.05mm Insulated Conductor
â2pcsâ, 6-up/2-down loading bar
The Snagless Cat 6A unshielded modular plugs accept from 24AWG to 26AWG stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.95mm to 1.05mm. âThe Snaglessâ prevents lots of cable snags when managing daily network distribution: move, add and change (MAC). It allows easy pulling through crowded distribution frames or cable management trays. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.70-0.80mm Insulated Conductor
w/SR for 4.5mm cable entrance
The âSmall Conductorâ Cat 6A unshielded modular plugs accept 26AWG and 28AWG slim cables. 28AWG UTP cable has a 0.69mm insulation diameter with nominal cable O.D. from 3.5mm to 4.8mm only. The 2-piece design has a âloading-barâ to accept from 0.70 to 0.80mm insulated conductors so all the thin wires can be placed on each slot. And the loading-bar is made in two rows - â6-up/2-downâ, moving the green pair away from the other pairs. 3-prong blades further enhance the certainty of piercing the slim cable so excellent conductivity can be assured. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades
-
For 0.55-0.60mm Insulated Conductor
w/SR for 4.0mm cable entrance
The âSmall Conductorâ Cat 6A unshielded modular plugs accept 28AWG and 30AWG ultra-slim cables. 30AWG cable has nominal insulations at approximately 0.53mm only. The 2-piece design has a âloading-barâ to accept from 0.55 to 0.60mm insulated conductors so all the thin wires can be placed on each slot. And the loading-bar is made in two rows - â6-up/2-downâ, moving the green pair away from the other pairs. Plug assembly that surpasses the Cat 6A specification is therefore feasible. 3-prong blades further enhance the certainty of piercing the ultra-slim cable so excellent conductivity can be assured. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades
-
For 1.00-1.10mm Insulated Conductor
â2pcsâ, 6-up/2-down loading bar
The âBig Conductorâ Cat 6A unshielded modular plugs accept from 23 to 26AWG, U/UTP solid or stranded twisted pair cable with accommodation of insulated conductor from 1.00mm to 1.10mm. The 2-piece design has a âloading-barâ to accept from 1.00 to 1.10mm insulated conductors so all the wires can be placed on each slot. And the loading-bar is made in two rows - â6-up/2-downâ, moving the green pair away from the other pairs. Plug assembly that surpasses the Cat 6A specification is therefore feasible. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
â3pcsâ, 1-row loading bar + windmill guide
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG, stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 3-piece design. Effective pair separation and maintaining the twist ratio are made possible by the "windmill guide". Together with the âloading barâ attached to it so each wire can be trimmed flush and steadily seated. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
â2pcsâ, 6-up/2-down loading bar
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG, stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The â6-up/2-down loading barâ is made in two rows. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
â3pcsâ, loading bar + windmill guide
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The âwindmill guideâ helps to separate each pair and keep its twist ratio. The âloading barâ is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
Plug includes Boot w/Icon
Plug + Ï6.7mm Boot + Boot Icon
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The âwindmill guideâ helps to separate each pair and keep its twist ratio. The âloading barâ is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
Plug includes Boot w/Icon + Cable SR
Plug + Ï6.7mm Boot + Boot Icon + Cable SR
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The âwindmill guideâ helps to separate each pair and keep its twist ratio. The âloading barâ is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.95-1.05mm Insulated Conductor
â2pcsâ, 6-up/2-down loading bar
The Snagless Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.95mm to 1.05mm. 2-piece design. The loading bar is made in two rows - â6-up/2-downâ. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. Each wire is trimmed flush and steadily seated. Plug assembly that surpasses the Cat 6A specification is therefore feasible. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 1.30-1.40mm Insulated Conductor
Cable Range: O.D.âŠ7.5mm
The Pass-Through Cat 6A shielded modular plugs are made to accept 23AWG S/FTP foamed wires with accommodation of insulated conductor from 1.30mm to 1.40mm. The Pass-Through plug gives you the convenience of threading the wires through the loading bar. The â1357-up/2468-down loading barâ is made in two rows. It eases the tension throughout the assembling procedure instead of aligning in a single row. Simply insert the bar all the way till it reaches the narrow gate and cut all wires afterward. Only a very short untwisted length is presented with no room for kink and slack. The extremely short stripped length is the secret to Cat 6A compliance. The external grounding hook is built at the rear for encircling the screened braid of S/FTP cable. The 360-degree shield surrounding favors the screen effectiveness and shield integrity that high-speed Ethernet requires. It works with 007A8401 Series Crimping Tool. Wire termination and cutting at the same time. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uâ gold plated contact blades - Supports PoE type 4 (PoE++) application - Must work with 007A8401 Series Crimping Tool
- Home Homepage
- This is HCI Company Profile
- Products Data Connectivity
-
Solutions Transmission Category
- UTP - ISO Cat 6a Component-Rated
- STP - ISO Cat 6a Component-Rated
- UTP - ISO-11801 Class Ea Cabling
- STP - ISO-11801 Class Ea Cabling
- UTP - TIA Cat 6A Component-Rated
- STP - TIA Cat 6A Component-Rated
- UTP - TIA Cat 6A Cabling Solution
- STP - TIA Cat 6A Cabling Solution
- UTP - Super Cat 6 Component-Rated
- STP - Super Cat 6 Component-Rated
- UTP - Super Cat 6 Cabling Solution
- STP - Super Cat 6 Cabling Solution