For 0.90-1.00mm Insulated Conductor
“3pcs”, loading bar + windmill guide
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm.
3-piece design.
The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit."
- UL Listed, TIA-1096 and IEC 60603-7 compliant
- PC UL94V-0 rated plug housing, 50u” gold plated contact blades
- Supports PoE type 4 (PoE++) application
88S201KS2B50
Cable Adaptability |
||
Insulated Conductor diameter range |
Cable Range |
Wire Gauge |
(0.9~1.0mm) 1.0mm |
5.5mm to 6.7mm |
24 to 26AWG |
Transmission Concern |
||
Pieces |
Load Bar |
Guide |
3pcs |
1-row load bar |
windmill guide |
- Material
-
Dielectric Withstanding Voltage
>1000 VAC
Insulation Resistance
>500 MΩ
Contact Resistance
<20mΩ
Operation Temperature
-10℃ to 60℃
Storage Temperature
-40℃ to 70℃
Durability
> 1000 mating cycles
EU Directive 2002/95/EC
RoHS Compliant
Safety Listing
RU Listed
- Dimensions
-
- Related Products
-
-
Plug includes Boot w/Icon
Plug + φ6.7mm Boot + Boot Icon
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
Plug includes Boot w/Icon + Cable SR
Plug + φ6.7mm Boot + Boot Icon + Cable SR
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The “windmill guide” helps to separate each pair and keep its twist ratio. The “loading bar” is made to attach to the guide so each wire can be trimmed flush and steadily seated. This may be the trick needed by many field installers to pass the "Cat 6A Patch Cord Test Limit." - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50u” gold plated contact blades - Supports PoE type 4 (PoE++) application
-
- Files Download
-
-