For 0.70-0.80mm Insulated Conductor
w/SR for 4.5mm cable entrance
The “Small Conductor” Cat 6A unshielded modular plugs accept 26AWG and 28AWG slim cables. 28AWG UTP cable has a 0.69mm insulation diameter with nominal cable O.D. from 3.5mm to 4.8mm only.
The 2-piece design has a “loading-bar” to accept from 0.70 to 0.80mm insulated conductors so all the thin wires can be placed on each slot. And the loading-bar is made in two rows - “6-up/2-down”, moving the green pair away from the other pairs.
3-prong blades further enhance the certainty of piercing the slim cable so excellent conductivity can be assured.
- UL Listed, TIA-1096 and IEC 60603-7 compliant
- PC UL94V-2 rated plug housing, 50u” gold plated contact blades
88U40360IC52
Cable Adaptability | ||
Insulated Conductor diameter range | Maximum Cable O.D. | Wire Gauge |
(0.71~0.8mm) 0.8mm | 6.5mm | 26 to 28AWG |
Transmission Concern | ||
Pieces | Load Bar | Guide |
2pcs | 6-up/2-down load bar | N/A |
- MaterialDimensionsRelated ProductsFiles Download
Dielectric Withstanding Voltage
>1000 VAC
Insulation Resistance
>500 MΩ
Contact Resistance
<20mΩ
Operation Temperature
-10℃ to 60℃
Storage Temperature
-40℃ to 70℃
Durability
> 1000 mating cycles
EU Directive 2002/95/EC
RoHS Compliant
Safety Listing
RU Listed