For 0.90-1.00mm Insulated Conductor
“3pcs”, one-row load bar + windmill guide
Standard Cat 6A unshielded modular plugs accept from 24AWG to 26AWG, stranded unshielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm.
3-piece design.
Effective pair separation and maintaining the twist ratio are made possible by the "windmill guide". Together with the “loading bar” attached to it so each wire can be trimmed flush and steadily seated.
- UL Listed, TIA-1096 and IEC 60603-7 compliant
- PC UL94V-2 rated plug housing, 50u” gold plated contact blades
- Supports PoE type 4 (PoE++) application
88U50H10AD52
Cable Adaptability | ||
Insulated Conductor diameter range | Maximum Cable O.D. | Wire Gauge |
(0.91~1.00mm), <1.10mm | 6.5mm | 23 to 26AWG |
Transmission Concern | ||
Pieces | Load Bar | Guide |
3pcs | 1-row load bar | windmill guide |
- MaterialDimensionsRelated ProductsFiles Download
Dielectric Withstanding Voltage
>1000 VAC
Insulation Resistance
>500 MΩ
Contact Resistance
<20mΩ
Operation Temperature
-10℃ to 60℃
Storage Temperature
-40℃ to 70℃
Durability
> 1000 mating cycles
EU Directive 2002/95/EC
RoHS Compliant
Safety Listing
RU Listed