Boot - SR201K10 is designed to precisely fit the shielded plug w/hook - 88S201KS1B50.
The boot is constructed with several locking holes that aid in positioning the locking protrudes located on the shielded plug w/hook - 88S201KS1B50.The boot is made of high-impact PC UL94V-0 material in order to firmly secure the wire-termination in place. The boot accepts shielded cables with a maximum cable O.D. up to 6.7mm. We offer Black and White for color options. Alternatively, you may skip stocking each color and just select the transparent color.
Boot Icon - SR201K20 is provided. Assign any given color for managing port identification on your network. Color options: Red, Orange, Yellow, Green, Blue, Purple, Black, Gray and Light Green
The Extended Strain Relief - SR201K3H is a smart choice for keeping the cable bending radius within a suitable angle range in order not to impact the transmission performance. We are well aware that an impedance problem and signal reflections result from too acute a bending radius. So, please always add a Cable SR when the patch cord is used in a relatively narrow space where sharp turn could likely occur.
- Material
-
Boot - SR201K10
Material
Up to 6.7mm Cable O.D.
Material
PC UL94V-0
Color Options
Black, White and Transparent
Storage Temperature
-40ā to 70ā
Boot Icon - SR201K20
Material
PBT UL94V-0
Color Options
Red, Orange, Yellow, Green, Blue, Purple, Black, Gray and Light Green
Storage Temperature
-40ā to 70ā
Cable SR - SR201K3H
Cable Adaptability
Up to 6.7mm Cable O.D.
Material
PVC 35% UL94 HB
Color Options
Transparent Red, Transparent Orange, Transparent Yellow, Transparent Green, Transparent Blue, Transparent Purple, Transparent Black, Transparent Gray and Transparent
Storage Temperature
-40ā to 70ā
- Dimensions
-
- Related Products
-
-
Plug includes Boot w/Icon
Plug + Ļ6.7mm Boot + Boot Icon
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The āwindmill guideā helps to separate each pair and keep its twist ratio. The āloading barā is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass āCat 6 Patch Cord Test Limitā. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50uā gold plated contact blades - Supports PoE type 4 (PoE++) application
-
Plug includes Boot w/Icon + Cable SR
Plug + Ļ6.7mm Boot + Boot Icon + Cable SR
Standard Cat 6 shielded modular plugs accept 24 to 26AWG, solid or stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm. 3-piece design. The āwindmill guideā helps to separate each pair and keep its twist ratio. The āloading barā is made to attach to the guide so each wire can be trimmed flush and steadily seated. For a lot of installers on the field, this could be the ingenuity to pass āCat 6 Patch Cord Test Limitā. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-0 rated plug housing, 50uā gold plated contact blades - Supports PoE type 4 (PoE++) application
-
For 0.90-1.00mm Insulated Conductor
ā2pcsā, 6-up/2-down loading bar
Standard Cat 6A shielded modular plugs accept from 24AWG to 26AWG, stranded shielded twisted pair cable with accommodation of insulated conductor from 0.90mm to 1.0mm and cable O.D. less than 6.5mm. 2-piece design. The ā6-up/2-down loading barā is made in two rows. It facilitates moving the green pair away from the other pairs. The most impedance-mismatched pair is put away so as to moderate the noises done to the other pairs. - UL Listed, TIA-1096 and IEC 60603-7 compliant - PC UL94V-2 rated plug housing, 50uā gold plated contact blades - Supports PoE type 4 (PoE++) application
-
-