Category 6
BP24NBI00B66M3
Compliant with Cat 6 TIA 568.2-D and ISO-11801 connecting hardware requirements.
24 plastic clips are attached to the cable manager to securely hold each cable in position without applying excessive stress that could potentially harm transmission performance. And the bendable side arms that help conserve packaging space.
The wire caps are provided to further secure the terminations, preventing them from being pulled out.
Supports IEEE 802.3bt 4PPoE application.
Unshielded Cat 6 Component-Rated Patch Panel w/Cable-Clips
Transmission Performance | ISO-11801 & TIA-568.2-D Cat 6 |
FCC & IEC Compliance | Meets FCC part 68-F & IEC60603-7 |
EU Directive 2002/95/EC | RoHS Compliant |
Safety Listing | UL Listed |
- Material
Panel SPCC 1.6t IDC Terminal Phosphor Bronze Spring Wire Phophor Bronze IDC Terminal Plating Nickel Spring Wire Plating 50u” Gold at Contact
Area Nickel UndercoatIDC Block Hi-impact PC UL94V-0 PCB FR-4 - Related Products
Category 6
BP24KHA6S
Considerations for running 802.3bz 5GBASE-T to support higher data rate of wireless AP would push the required bandwidths to 312MHz, well above the 250MHz specification of ANSI/TIA 568.2-D and ISO/IEC-11801 Category 6.HCI Super Cat 6 Component-Rated patch panel go beyond extended bandwidth for up to 350MHz.It features Inductance-offset technique to reduce fringing field and to improve NEXT, FEXT and Return Loss. This technique is US 9325117 B1 patented.Made in Taiwan ETL Certified Cat 6 Connecting Hardware & Quarterly Tested 4PPoE Compliant US 9325117 B1 Patented
Category 6
SP24F2KHA6SM
Front-Access design offers the convenience for pulling bulk cables from the rear when the panel is fixed on rack.SP24F is designed to work with KHA series as combo package to go beyond extended bandwidth for up to 350MHz.KHA series Component-Rated jacks feature Inductance-offset technique to reduce fringing field and to improve NEXT, FEXT and Return Loss. This technique is US 9325117 B1 patented.Made in Taiwan ETL Certified Cat 6 Connecting Hardware & Quarterly Tested 4PPoE Compliant US 7278880 B1 / US 9325117 B1 Patented
Category 6
SP24F2KVA6SM
Front-Access design offers the convenience for pulling bulk cables from the rear when the panel is fixed on rack.SP24F is designed to work with KVA series as combo package to go beyond extended bandwidth for up to 350MHz.KVA series Component-Rated jacks feature Inductance-offset technique to reduce fringing field and to improve NEXT, FEXT and Return Loss. This technique is US 9391405 B1 patented.Made in Taiwan ETL Certified Cat 6 Connecting Hardware & Quarterly Tested 4PPoE Compliant US 7278880 B1 / US 9391405 B1 Patented
- Files Download